水力发电学报 ›› 2016, Vol. 35 ›› Issue (1): 63-69.doi: 10.11660/slfdxb.20160108
• 水力发电 • 上一篇 下一篇
出版日期:
发布日期:
Online:
Published:
Abstract: Flow at the outlet of a drop shaft structure is difficult to achieve uniformity under the influence of its bend and straight sections. Meanwhile, reverse flow tends to occur near the diversion orifices. A RNG k-ε turbulence model was adopted in this study with experimental verification to make a three-dimensional numerical simulation on flow characteristics near the bend outlet of a drop shaft, and the effects of bend type and straight pipe length on the flow uniformity have been analyzed. The results show that if the length of straight pipe section is fixed at 2D (D is the diameter of straight pipe), a bend of gradual contraction can produce more uniform outflow than a regular bend of equal diameter (fixed and equal to the diameter of contraction outlet). If equal diameters are adopted, the outflow uniformity of two bends is comparable when the length of straight pipe adds 6D ~ 8D. The results are significant in guidance for design of the drop shaft inlet and outlet of pumped storage plants.
高学平,刘际军,张翰,田野. 具有弯道的竖井式出水口水流均匀性研究[J]. 水力发电学报, 2016, 35(1): 63-69.
GAO Xueping, LIU Jijun, ZHANG Han, TIAN Ye. Study on flow uniformity at bend outlet of drop shaft structure[J]. JOURNAL OF HYDROELECTRIC ENGINEERING, 2016, 35(1): 63-69.
0 / / 推荐
导出引用管理器 EndNote|Reference Manager|ProCite|BibTeX|RefWorks
链接本文: http://www.slfdxb.cn/CN/10.11660/slfdxb.20160108
http://www.slfdxb.cn/CN/Y2016/V35/I1/63