水力发电学报 ›› 2015, Vol. 34 ›› Issue (1): 93-98.
• 水力学、水环境与泥沙研究 • 上一篇 下一篇
出版日期:
发布日期:
Online:
Published:
Abstract:
Surge tank is a structure crucial to the stability of governing system and regulation quality. Thomas critical stable section area is a significant design criteria, but it neglects the effect of water interia in surge tank. This inertia could affect stable section area and governing quality if a surge tank has a long lateral pipe connecting to the intake tunnel, such as in a pumped storage station or high water head hydropower station. By theoretical analysis, numerical computation and engineering example in this paper, it is proved that the water inertia in a surge tank with a long lateral pipe helps to decrease the stable section area and improve regulation quality in small fluctuations and that neglect of water inertia in design is safer.
王 超,杨建东. 连接管长度对调压室稳定面积和小波动调节品质的影响[J]. 水力发电学报, 2015, 34(1): 93-98.
WANG Chao, YANG Jiandong . Effect of lateral pipe length of surge tank on its stable section area and regulation quality[J]. JOURNAL OF HYDROELECTRIC ENGINEERING, 2015, 34(1): 93-98.
0 / / 推荐
导出引用管理器 EndNote|Reference Manager|ProCite|BibTeX|RefWorks
链接本文: http://www.slfdxb.cn/CN/
http://www.slfdxb.cn/CN/Y2015/V34/I1/93
Cited