摘要: 为减轻分布式泵群停电产生的负水锤对供水系统的危害,提出了一种单向塔和空气阀联合防护的方案,明确了单向塔的防护效果,给出了主管集中段设置空气阀的基本公式,并以坦桑尼亚城市供水工程为研究对象,通过数值模拟的方法,验证了其合理性。研究结果表明:单向塔和空气阀的联合防护相较于单一的单向塔防护,效果更好,可以大幅减少工程造价;单向塔直径和连接管直径均需结合实际工程进行参数优选。
关键词: 复杂供水系统, 分布式, 负水锤, 单向塔, 空气阀
Abstract: To reduce the damage to a water supply system caused by negative water hammers that occur in its distributed pump group after power outage, a new joint protection scheme using a one-way tower and an air valve is described. The effect of one-way tower protection is clarified and a basic formula for setting the air valve in a main pipe concentration section is presented. This scheme is verified through numerical simulations in a case study of the urban water supply project in Tanzania. The results show that the protection by adopting both a one-way tower and an air valve is more effective than that adopting a one-way tower alone, and it reduces the project cost greatly. The diameters of the one-way tower and its connecting pipes should be optimized according to the conditions of a practical project.
Key words: complex water supply systems, distributed pump group, negative water hammer, one-way tower, air valve
仇为鑫, 潘益斌, 张健. 分布式供水泵群水锤防护计算研究[J]. 水力发电学报, 2022, 41(3): 101-112.
QIU Weixin, PAN Yibin, ZHANG Jian. Protection against water hammers for distributed pump group in water supply system[J]. Journal of Hydroelectric Engineering, 2022, 41(3): 101-112.